- Buy Online
- |
- fr
- |
- USA
- |
- Home>
- Marketing Tools >
- Aesthetic>
- Aesthetic Equipments >
- Eclipsia +
Eclipsia +
Product Code: 01-1475
ADVANCED THERMOCOAGULATION SYSTEM
A more advanced, more efficient and more comfortable thermocoagulation technology than those currently available in the market, this is what you get with the Eclipsia+ 27.12 MHz. This innovative system, using the 27.12 MHz ultrafast radiofrequency, provides for a quick and safe cosmetic treatment of all types of skin imperfections such as telangiectasis, spider veins, cherry angiomas, milia, keratosis, skin tags, pigmentation spots and minor acne problems.
FASTER RESULTS
The Eclipsia+ advanced thermocoagulation system uses a 27.12 MHz ultrafast radiofrequency to quickly eliminate all types of superficial skin imperfections. Since this frequency is up to 7 times faster than the frequency used by competitor systems, the Eclipsia+ generates the required energy in less time than other devices in its category, thus producing quicker and better coagulation results.
INCOMPARABLE COMFORT
Thanks to its 27.12 MHz ultrafast radiofrequency and exclusive application techniques, the Eclipsia+ offers an unparalleled level of comfort. In fact, the treatment is performed so quickly that the sensation is barely noticeable by the patient. Mere thousandths of a second are enough to eliminate the unwanted imperfection! By offering such a high level of comfort, the Eclipsia+ has become the preferred solution for all body areas and types of patients, including the most sensitive ones!
SAFE AND CONVENIENT TREATMENT
The powerful Eclipsia+ 27.12 MHz radiofrequency is controlled by a microprocessor capable of delivering very short pulses in thousandths of a second, compared to other devices where heat diffusion is up to one hundred times longer, causing more irritation and pain. The Eclipsia+ 27.12 MHz radiofrequency is so fast that it minimizes collateral damage in the tissues and skin reactions on the surface, all this without the necessity of using topic analgesics. In this manner, the patient does not experience any secondary effects or periods of recuperation.
WHY USE THE ISM 27.12 MHz FREQUENCY?
The main advantage of this frequency is the ultrafast change of polarity, from positive to negative, represented by its 27 million cycles (Hertz) per second. The ultrafast polarity change distinguishes the Eclipsia+ from others since it coagulates tissues much faster than conventional devices. This speed allows extremely fast application times, making the cosmetic treatment of skin imperfections much more comfortable. Moreover, extensive research shows that at 27.12 MHz, the destruction zone is concentrated closer to the probe, where the imperfection is located. Since the neighbouring tissues are not affected by heat, the comfort is unparalleled. At 3 or 4 MHz, a larger model of heat is produced. This heat penetrates much deeper into the skin, thus inducing discomfort and unwanted collateral skin reactions. Another technical explanation is the fact that the 27.12 MHz frequency allows for a better absorption of the power by the water molecules contained in the skin. It then takes less power at a frequency of 27.12 MHz to perform a thermocoagulation treatment than it would at a slower frequency. With the same amount of power, the 27.12 MHz signal is then applied for a shorter period of time, which increases the level of comfort for the patient and reduces the risk of undesirable skin reactions.
BENEFITS FOR PATIENTS
• Very comfortable cosmetic skin treatment due to the 27.12 MHz ultrarapid frequency.
• Immediate visible results.
• Safe on any skin type and color.
• No undesired skin reaction when performed properly.
• No local anaesthesia needed.
• No compression stockings or bandages needed.
• No side effects or allergies.
• No recuperation time, because skin regeneration is very rapid in the days following the treatment.
• Powerful circuit with 27.12 MHz ISM monopolar frequency.
• Fully microprocessor controlled.
• Control of treatment time in thousandths of a second.
• Unique TeleFlash, MultiCoagul, Synchro and Cata+ modes.
• Handy Flip-Top design aluminum cabinet.
• Accessory supports.
• Universal power adapter.
• Color touch screen and user friendly navigation.
• Quick return on investment.
• Meets international standards.
CLINICAL STUDY
Telangiectasia|After 1 treatment
* Only the treatment of skin vascular imperfection is registered at Health Canada.
FASTER RESULTS
The Eclipsia+ advanced thermocoagulation system uses a 27.12 MHz ultrafast radiofrequency to quickly eliminate all types of superficial skin imperfections. Since this frequency is up to 7 times faster than the frequency used by competitor systems, the Eclipsia+ generates the required energy in less time than other devices in its category, thus producing quicker and better coagulation results.
INCOMPARABLE COMFORT
Thanks to its 27.12 MHz ultrafast radiofrequency and exclusive application techniques, the Eclipsia+ offers an unparalleled level of comfort. In fact, the treatment is performed so quickly that the sensation is barely noticeable by the patient. Mere thousandths of a second are enough to eliminate the unwanted imperfection! By offering such a high level of comfort, the Eclipsia+ has become the preferred solution for all body areas and types of patients, including the most sensitive ones!
SAFE AND CONVENIENT TREATMENT
The powerful Eclipsia+ 27.12 MHz radiofrequency is controlled by a microprocessor capable of delivering very short pulses in thousandths of a second, compared to other devices where heat diffusion is up to one hundred times longer, causing more irritation and pain. The Eclipsia+ 27.12 MHz radiofrequency is so fast that it minimizes collateral damage in the tissues and skin reactions on the surface, all this without the necessity of using topic analgesics. In this manner, the patient does not experience any secondary effects or periods of recuperation.
WHY USE THE ISM 27.12 MHz FREQUENCY?
The main advantage of this frequency is the ultrafast change of polarity, from positive to negative, represented by its 27 million cycles (Hertz) per second. The ultrafast polarity change distinguishes the Eclipsia+ from others since it coagulates tissues much faster than conventional devices. This speed allows extremely fast application times, making the cosmetic treatment of skin imperfections much more comfortable. Moreover, extensive research shows that at 27.12 MHz, the destruction zone is concentrated closer to the probe, where the imperfection is located. Since the neighbouring tissues are not affected by heat, the comfort is unparalleled. At 3 or 4 MHz, a larger model of heat is produced. This heat penetrates much deeper into the skin, thus inducing discomfort and unwanted collateral skin reactions. Another technical explanation is the fact that the 27.12 MHz frequency allows for a better absorption of the power by the water molecules contained in the skin. It then takes less power at a frequency of 27.12 MHz to perform a thermocoagulation treatment than it would at a slower frequency. With the same amount of power, the 27.12 MHz signal is then applied for a shorter period of time, which increases the level of comfort for the patient and reduces the risk of undesirable skin reactions.
BENEFITS FOR PATIENTS
• Very comfortable cosmetic skin treatment due to the 27.12 MHz ultrarapid frequency.
• Immediate visible results.
• Safe on any skin type and color.
• No undesired skin reaction when performed properly.
• No local anaesthesia needed.
• No compression stockings or bandages needed.
• No side effects or allergies.
• No recuperation time, because skin regeneration is very rapid in the days following the treatment.
FEATURES
• 6400 programs for face and body.• Powerful circuit with 27.12 MHz ISM monopolar frequency.
• Fully microprocessor controlled.
• Control of treatment time in thousandths of a second.
• Unique TeleFlash, MultiCoagul, Synchro and Cata+ modes.
• Handy Flip-Top design aluminum cabinet.
• Accessory supports.
• Universal power adapter.
• Color touch screen and user friendly navigation.
• Quick return on investment.
• Meets international standards.
CLINICAL STUDY
Telangiectasia|After 1 treatment
Campbell spot|After 1 treatment
Keratosis|After 1 treatment
Skin tag|After 1 treatment
Cherry angioma|After 1 treatment
Keratosis|After 1 treatment
Skin tag|After 1 treatment
Cherry angioma|After 1 treatment
PROGRAMS | ACCESSOIRES |
10 anomalies (man - woman - face - body) 2 types of probes (INOX, ITH) 4 probe calibers Customizable programs (90/users) ELECTRONIC CIRCUIT Exclusive 27.12 MHz radio frequency Response time in milliseconds Progressive galvanic current Automatic compensation based on moisture level Microprocessor MP/XCL-25 Watch Dog XCL safety system Meets international standards Universal power supply FUNCTIONS Skin moisture test and accessory test U.L. and ?.L. display Automatic mode 2 outputs for probes | 1 short K probe-holder (04-3001) 1 red cord (04-004) 1 black cable (04-014) 1 bar electrode (04-015) with sponge tissue (04-013) 1 plate electrode (04-01133) with sponge tissue (04-0122) 1 set of 4 multifunction electrodes (04-01809) 2 rubber supports fitted to the device - left (6070-3001120) - right (6070-3001125) 1 Dectro Dome Footswitch (04-034) 1 disposable Pro-Tec container (03-002) 1 Power supply 100-240 VAC 50-60 Hz 1.4-0.7A 1 user manual 1 stylus (04-0291) 1 warranty card DESIGN Color touch screen and user friendly navigation Handy Flip-Top design aluminum cabinet Accessory supports |
WEIGHT
17 lb (7,71 kg)
DIMENSIONS
Height
open: 40 cm (15,7 po) closed: 17 cm (6,7 po)
Width
open: 42 cm (16,5 po) closed: 42 cm (16,5 po)
Depth
open: 31 cm (12,2 po) / closed: 39 cm (15,4 po)
17 lb (7,71 kg)
DIMENSIONS
Height
open: 40 cm (15,7 po) closed: 17 cm (6,7 po)
Width
open: 42 cm (16,5 po) closed: 42 cm (16,5 po)
Depth
open: 31 cm (12,2 po) / closed: 39 cm (15,4 po)